Multifunction Self-lock Relay Timer Switch Module, 12VDC

Code ABT04
  • Manufacturer Unspecified
  • ID code Does not apply
  • Weight 27.00g

E-shop price: 12,95

Amount: 4+ 8+
Price: 12,17 11,79
Minimum order: 1 Repeatability : 1

Amount
Item location:
Central warehouse in Kaunas Item available (3)
Shop in Vilnius Item available (3)
Shop in Kaunas Item available (2)

Item description

This multifunction relay control module , designed specifically for a variety of users with different needs, the use of micro-controller as the master unit, preset 18 kinds if functions, and can be based on user needs,customize and add other specific functions

Power relay module using high quality, high-voltage power transistor, red, blue signal lights, double-sided PCB board,cloth board to consider a comprehensive, stable performance, can be widely used in a variety or power control types of occasions

Features:

New upgrade to version 2.0, the module features the eight kinds before, increased to 18 kinds, to meet the needs of more applications

Increase the supply anti-reverse function, and does not take the wrong power supply is damaged module

The use of top-quality high-voltage power supply modules, discrete power supply before replacing the system more stable and reliable;

Increased 0.1 seconds timing, timing accuracy from the previous 0.1 seconds, upgrade to 0.01 seconds

Increase automatic power saving feature, users can independently set

1)The module function:

Users can display the key and select the following 18 kinds of functions in one, you can set and save function parameters, you can also view the parameters of the current function of the time parameter sets the minimum 0.1 seconds adjustable accuracy better than 0.01 seconds, with regard to the specific Set operating instructions, can be obtained from vendors.

Tips:Function 1-8 start at power on their own, functional 9-18 need high pulse signal (high duration shorter than 20ms, the same applies hereinafter) is triggered to start.

Function 1:

Timing Pick: After power-up, the time delay relay T1, T1 between 0.1 seconds -270 hours adjustable, CH1 interfaces to a high level pulse signal, repeat the above functions

Function 2:

Timing off: When the power relay, time delay relay disconnected T1, T1 between 0.1 seconds -270 hours adjustable, CH1 interfaces to a high level pulse signal, repeat the above functions

Function 3:

Re-timed pull off: After power relay to not pull, the delay time T1 reaches relay; pull off the relay T2 arrives, the delay time T1 and T2 in 0.1 seconds -270 hours adjustable from an interface to CH1 High pulse signal, repeat the above functions

Function 4:

Then pull off the timing: After power, immediately pull the relay, the relay off after the delay time T1 arrive; arrive after disconnecting relay time T2, -270 hour in 0.1 seconds delay time between T1 and T2 Adjustable, CH1 interfaces to a high level pulse signal, repeat the above functions

Function 5:

Infinite loop timing mode 1: After power relay to not pull, the delay time T1 reaches relay; pull off the relay T2 arrives, and then repeat the above condition, the delay time T1 and T2 at 0.1 Adjustable seconds between -270 hours, to a high level pulse signal CH1 interface, you can restart the above functions

Function 6:

Infinite Loop Timing Mode 2: After power, immediately pull the relay delay time T1 reaches the relay off; arrive after disconnecting relay time T2, and then repeat the above condition, the delay time T1 and T2 in 0.1 seconds adjustable between -270 hours, to a high level pulse signal CH1 interface, you can restart the above functions

Function 7:

Finite loop timing mode 1: Based on the function 5, increasing the number of cycles feature, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable, NX cycles adjustable between 1-9999 times, the interface to CH1 a high level pulse signal, these functions can be re-started

Function 8:

Finite loop timing mode 2:6 function on the basis of increased functionality cycles, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable, NX cycles adjustable between 1-9999 times, the interface to CH1 a high level pulse signal, these functions can be re-started

Function 9:

Latching relay modes: CH1 interfaces to relay a high level pulse signal, the relay, to give a high level pulse signal relay disconnected.

Function 10:

Trigger relay modes: CH1 interfaces to a high signal relay, relay, high disappear, relay disconnected.

Function 11:

Pull trigger timing: After power relay does not act, CH1 interfaces to a high level pulse signal, the time delay relay T1, T1 in adjustable between 0.1 seconds -270 hours, a high-level interface to repeat to CH1 pulse signal, repeat the above function

Function 12:

Trigger timing off: After power relay does not act, a high-level interfaces to CH1 pulse signal relay, the relay off delay time T1, T1 between 0.1 seconds -270 hours adjustable, repeat to CH1 Interface a high level pulse signal, repeat the above functions

Function 13:

Pull the trigger and then disconnect the timing: After power relay does not act, the interface to a high level pulse signal CH1, arrived after the delay time T1 relay; pull off relay arrives after T2, T1 and delay time T2 is adjustable between 0.1 seconds -270 hours, repeat the interface to a high level pulse signal CH1, repeat the above functions

Function 14:

Disconnect and then pull trigger timing: After power relay does not act, the interface to a high level pulse signal CH1, immediately pull the relay, the relay off after the delay time T1 arrive; arrive after disconnecting relay time T2, delay time between T1 and T2 -270 hours adjustable 0.1 seconds, repeat the interface to a high level pulse signal CH1, repeat the above function

Function 15:

Infinite loop timing mode 1: After power relay does not act, give a high level pulse signal CH1 interfaces, the delay time T1 reaches relay; pull the relay off time T2 arrive, and then repeat the above state, the extension When the time between T1 and T2 -270 hours adjustable 0.1 seconds, repeat the interface to a high level pulse signal CH1, the above function can be restarted

Function 16:

Infinite Loop Timing Mode 2: After power relay does not act, CH1 interfaces to a high level pulse signal, immediately pull the relay, the relay off after the delay time T1 arrive; break time T2 after reaching relay, then Repeat the above state, the delay time between T1 and T2 -270 hours adjustable 0.1 seconds, repeat the interface to a high level pulse signal CH1, the above function can be restarted

Function 17:

Finite loop timing mode 1:15 on the basis of functionality, increasing the number of cycles feature, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable, NX cycles adjustable between 1-9999 times, repeating to CH1 interface to a high pulse signal, you can restart the above functions

Function 18:

Finite loop timing mode 2: 16 on the basis of functionality, increasing the number of cycles feature, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable, NX cycles adjustable between 1-9999 times, repeating to CH1 interface to a high pulse signal, you can restart the above functions

2)Module Interface :

Module control terminal: 3-wire interface, all interfaces are terminal, user-friendly

1, DC +: DC power positive

2, DC-: negative DC power supply

3, CH1: input detection interfaces, active high

Relay outputs: 3-wire interface, all interfaces are terminals

1.NO: normally open relay interface, the relay before the vacant after short pull with COM1

2.COM: Common Interface Relays

  1. NC: normally closed relay interface COM1 relay shorted before and after the pull-vacant

Load capacity: normally open port maximum load capacity: DC 0-30V/10A, AC 0-250V/10A

NC port maximum load capacity: DC 0-28V/10A, AC 0-125V/10A

3)Specification:

Operating Voltage: 12V

Working Current: 12V/less than 50mA(When the relay is not operating less then 15mA, turn off the dsiplay less then 3mA)

Working Temperature:-20-60degree(Limit range -30-70degree)

Load capacity:

the module normally open nterface maximum load capacity: DC 0-30V/10A,AC0-250V/10A

the module normally closed nterface maximum load capacity: DC 0-28V/10A,AC0-125V/10A

Specification